Consumul Biochimic de Oxigen |
| |
|
 |
Determinarea O2 dizolvat in apa |
 |
Dissolved O2 in water |
 |
تحديد الاوكسجين المنحل في الماء |
|
| |
| |
|
| |
|
| |
Articole corelate |
| |
Prelevare apei |
| • Echipamente si ustensile pentru prelevare apa si lichide |
| |
| |
| |
| Pentru orice detalii suplimentare tehnice sau comerciale va rugam sa ne contactati: |
 |
|
| Sisteme de masurare consumului bioligic de O2 |
| consumul biologic de oxigen, reprezintă cantitatea de oxigen consumată de microorganisme pentru descompunerea biochimică a substanţelor organice din apă, în timp de 5 zile, la 20°C (condiţii standard). |
| |
 |
 |
Masurarea consumului biochimic de oxigen |
| |
modele: OxiTop 6 si OxiTop 12 |
| |
Principiul de masurare este masurarea presiunii intr-un sistem inchis: microorganismele din proba consuma oxigenul si formeaza CO2. acesta este absorbit de NaOH, astfel rezulta o scadere a presiunii ce este citita direct ca o valoare in mg/l CBO. aparatul are: • 1 senzor de presiune piezoelectric.
• 2 taste de operare: M (afisarea valorii momentane) si S (afisarea valorii stocate)
• afisajul LED afiseaza diviziuni de scala de la 00 la 50 (o diviziune de scala corespunde la 3.55 hPa).
• memorie cu 5 masuratori la intervale zilnice
• masurarea automata; nu este nevoie ca masuratorile sa fie oprite in fiecare zi intrucat
ce permite efectuarea masuratorilor si in lipsa operatorului, fara supraveghere. se pot efectua si determinari dupa 7 zile (CBO7).
• functie "AutoTemp": pornirea intarziata (programata) a masuratorilor in cazul probelor prea reci. OxiTop intarzie pornirea masuratorilor pana ce se atinge o temperatura constanta; perioada minima de intarziere este 60 minute. |
| |
|
|
 |
BOD - COD Biochimical Consumption Measurement |
| |
Models: OxiTop 6 and OxiTop 12 |
| |
DIN method. Simple, automatic operation.
No dilutions required. Has all advantages of manometric measuring system - Mercury free. Integrated datalogger.
Range 0-10,000 mg/L BOD. Internal battery - life >3 years. Sets of 2,6 or 12. |
| |
|
|
|
|
 |
 |
Masurarea consumului biochimic de oxigen |
| |
modele: OxiTop IS 6 si OxiTop IS 12 |
| |
Kit complet (ready to use) la 220V/50Hz cu 6 sau 12 pozitii constand din:
• 6 sau 12 capete de masura OxiTop cu dispay unit 0..50 digiti; • sistem de agitare IS 12;
• 12 sticle; • 12 garnituri; • 12 bare magnetice s.a.
• Principiu de masura: manometru cu senzor de presiune • Domeniu de masura: 0...4000 mg/l • Precizie: 1 mg/l
• Domeniu temperatura: pentru lucru +5...+50°C; pentru stocare -25...+65°C |
| |
|
|
 |
BOD - COD Biochimical Consumption Measurement |
| |
Models: OxiTop IS 6 and OxiTop IS 12 |
| |
Measurement using OxiTop is based on pressure measurement in a closed system: microorganisms in the sample consume the oxygen and form CO2. This is absorbed by NaOH, creating a vacuum which can be read directly as a measured value in mg/l BOD. |
| |
|
|
|
|
 |
 |
Masurarea consumului biochimic de oxigen |
| |
modele: OxiTop Control 6 si OxiTop Control 12 |
| |
Foloseste program de control "Achat OC" si interfata IR pentru comunicarea cu controlerul OC-100 si OC-110.
Functie "AutoTemp" numar propriu de identificare permite intarzierea pornirii masuratorilor cu pana la 4 ore in cazul probelor prea reci poate stoca pana la 360 seturi de date; datele sunt memorate automat in intervalul de timp corespunzator, in conformitate cu perioada de timp setata (0,5 ore la 99 zile) senzorul de presiune poate inregistra diferente de presiune pe un domeniu cuprins intre 500 si 1350 hPa |
| |
|
|
 |
BOD - COD Biochimical Consumption Measurement |
| |
Models: OxiTop Control 6 and OxiTop Control 12 |
| |
Uses software controlled functions and an infrared interface to communicate with a handy controller, the OC 100 and OC 110.
This BOD instrumentation system enables the simultaneous and grouped start, management, storage and tracking of 100 BOD measuring heads via the controller and allows them to be tracked on a large display with graphic evaluation.
BOD measurement data can be transferred to the PC for evaluation and documentation via the AK-540/B cable (order no. 902842) and the communication program Achat OC |
| |
|
|
|
|
 |
 |
OxiTest |
| |
Controlor OC 100 si OC 110 |
| |
aparat de pornirea, monitorizarea, stocarea si controlul simultane si grupate a pana la 100 capete de masurare OxiTop valorile masurate pot fi verificate permanent, chiar si in timpul masuratorii, astfel incat eventualele erori si interferente pot fi detectate intr-un stadiu incipient al determinarii, permitand corectarea procesului de masurare calculul automat si afisarea grafica a valorii CBO protocol si documentarea datelor prin intermediul programului Achat OC (optional) si a unui PC GLP si sistem de asigurare a calitatii cu intervale de inspectie pentru calibrare |
| |
|
|
 |
OxiTest |
| |
|
| |
|
| |
|
|
|
|
 |
 |
Reactie Redox CBO5 - COD - BOD |
| |
Sistemul BOD Sensor System 6 |
| |
Valorile masurate sunt exprimate si afisate direct in mg/l.
Valorile CBO5 (ppm) pot fi afisate in fiecare zi, chiar si dupa perioada standard de 5 zile.
Dupa determinarea valorilor de BOD5 este posibila si determinarea BOD-ului total.
Materialul de constructie este din otel inox protejat un strat de epoxy ceea ce-I confera o rezistenta foarte buna impotriva coroziunii chimice
Motorul permite o agitare continua, fara riscul unor intreruperi sau supraincalziri ceea ce ar putea afecta rezultatele determinarilor BOD. |
| |
|
| |
-- vezi detalii |
|
 |
BOD - COD Biochimical Consumption Measurement |
| |
BOD Sensor Systems 6 consist of 6 position stirring unit complete with 6 BOD Sensors, 6 alkali holders for absorbing the carbon dioxide and 6 stirring bars.
The instrument represents a complete solution for the user.
It is immediately operational for measuring the BOD on 4 scales - 90, 250, 600 and 999 ppm BOD - higher values can also be measured by diluting the sample.
The sample quantity to be examined varies from 100 to 400 ml, and the bottle’s total capacity is 500 ml.
The compact, easy-to-handle design means that 6 BOD bottles can be housed in a small amount of space.
The instrument features a stirring system offering non-stop operation without risks of shut-off or overheating. |
| |
|
| |
-- details |
|
|
|
|
|
 |
 |
Termoreactor / determinarea COD |
| |
Termoreactoare COD pentru procese de digestie chimice |
| |
|
| |
|
|
|
|
|
| Despre oxigenul dizolvat in apa |
| Determinarea cantitatii de oxigen dizolvat in apa (dissolved oxygen | DO) este esentiala in analiza apelor deoarece oxigenul este necesar supravietuirii si cresterii multor organisme.
Pentru aceasta determinare sunt folosite de obicei doua standarde bazate pe aceeasi procedura, dar folosind concentratii diferite ale reactivilor. |
| |
• Cantitatea de oxigen dizolvat in apa variaza in functie de presiunea atmosferica, de temperatura apei, de continutul in saruri minerale si substante organice, etc. • Oxigenul are o solubilitate relativ scazuta in apa (invers proportionala cu temp. apei !!);
pentru anumite valori particulare de temperatura, salinitate si presiune atmosferica, canitatea de oxigen dizolvata in apa reprezinta concentratia de echilibru (saturatie).
• fluctuatiile in timp ale saturatiei in oxigen sunt dependente si de:
- eliberarea de oxigen rezultat in urma fotosintezei (macrofite + alge)
- consumul de oxigen al organismelor din ecosistem
- adancimea si stratificarea apei (in perioada de iarna, important pt. iazurile piscicole cu zone adanci)
- incarcatura apei in substante organice
- incarcatura apei cu agenti puternic reducatori, care apar in cazul iazurilor cu depozite de mal organic si stratificare a apei: hidrogen sulfurat (H2S), sulfat feros (FeS), metan (CH4) 5
- cantitatea de oxigen dizolvata in apa se exprima de obicei in miligrame oxigen/litru (mg/l) la presiunea de 760 mmHg |
| |
|
|
|
| Multi-Lab© SRL Romania | 2003 -2011 All rights reserved. |
| Calitatea apelor Calitatea apelor este stabilita prin standarde, datorita importantei pe care o prezinta pentru siguranta vietii si pentru desfasurarea activitatilor economice. In România sunt în vigoare: STAS 1342 - 91 pentru calitatea apei potabile, STAS 4706 - 88 pentru apele de suprafata, STAS 9450 - 73 pentru apele necesare irigatiilor, Norme de igiena pentru stranduri organizate si o serie de decrete, pentru precizari. Calitatea apelor se exprima prin indicatori, stabilizati si calculati în urma unor analize efectuate atât la apele de suprafata, cât si la cele subterane. La apele de suprafata se determina: - indicatori organoleptici; - suspensii; - pH; - CCO; - oxigenul dizolvat; - CBO; - azotul total; - analize biologice, toxicologice, bacteriologice, de radioactivitate, eutrofizare, etc. La apele subterane se determina: - pH-ul; - reziduul fix; - CCO. In anumite situatii se mai analizeaza din ape urmatoarele continuturi de substante: detergenti, pesticide, metale neferoase, fenoli, hidrocarburi, clor, azotat, fluor, iod, fier, mangan, indicatori de eutrofizare, etc. Indicatorii organoleptici sunt: culoarea apei, gustul si mirosul. Suspensiile din apa se determina dupa sedimentare si se exprima în ml/ l. pH-ul reprezinta reactia acida, neutra, sau bazica a apei, deoarece: pH = - log / H+/ unde /H+/ reprezinta concentratia ionilor de hidrogen din solutie. Mediul acid are pH < 7, mediul neutru are pH = 7, iar cel bazic, pH > 7. CCO reprezinta consumul chimic de oxigen, respectiv cantitatea de substante ce se pot oxida la rece, sau la cald, sub actiunea unor oxidanti ca KMnO4, sau K2Cr2O7 (mg/l). Oxigenul dizolvat în apa se exprima în mg/ l. Continutul de oxigen dizolvat în apa scade cu cresterea temperaturii astfel: la 00 C - 14,65 mg O2/dm3, la 100 - 11, 27; la 200 - 9,02; la 300 - 7,44. Conform prevederilor STAS 4706 - 88, limita continutului de oxigen de la care o apa se considera degradata este de 6 mg / dm3 . CBO5 20 - consumul biologic de oxigen, reprezinta cantitatea de oxigen consumata de microorganisme pentru descompunerea biochimica a substantelor organice din apa, în timp de 5 zile, la 20°C (conditii standard). Se calculeaza astfel: mg CBO / dm3 = A - B unde: A - oxigenul din apa recoltata; B - oxigenul ramas în apa dupa 5 zile. CBO este un indicator mult utilizat pentru caracterizarea apelor, deoarece arata daca apa poate fi epurata biologic, sau nu. Daca CBO5 este 0,6 mg/ dm3, atunci apa se poate epura biologic usor; daca este 0,2 - 0,4 epurarea biologica trebuie favorizata de temperatura, iar daca este sub 0,2 - apa nu este epurabila biologic. Analizele biologice determina fero - si sulfobacteriile, protozoarele, plantele si animalele din apa analizata. |
| oxigenometru Portabil, analiza redox, oxigenometre apelor potabile, O2 apelor reziduale, Fotometrice, Spectrofotometrice, conditiile mediului de lucru, plasmatice pentru determinarea componentelor Cx Hy din gaze de ardere, gaze de esapament, aerul ambiant interior si exterior si alte instalatii de reciclare a diluantilor, oxigenometru DR.LANGE, teste cuveta pentru determinare de oxigen chimic, metale grele, amoniu, fosfat; pentru obtinerea constantelor si a factorilor necesari masurarii concentratiei unui ion intr-o solutie apoasa, Julabo, Brand, Schott, Systec, DR SCHLEUNIGER, Barnstead, GFL, oxigenometru HANNA, oxigenometru WTW, Analizor de clor rezidual in apa. Analizorul de clor . |